Poly Rove B2, Base station DECT, Single/Dual
2200-86820-101
Poly Rove B2 — a DECT base station for single or dual cell deployment. It handles up to 10 simultaneous calls in single cell mode and extends with up to six R8 repeaters. The power adapter is in the box.
Single or dual cell
Up to 10 simultaneous calls, single cell
Coverage up to 465 m², dual cell up to 1,390 m²
Up to six R8 repeaters
DECT band 1880 to 1900 MHz
Power adapter in the box
Order code | Product | Type | Deployment | Simultaneous calls | Power |
|---|---|---|---|---|---|
8J8W3AA#ABB | Rove B2 (this product) | base station | single or dual cell | up to 10, single cell | adapter in the box |
8J8W4AA#ABB | Rove B4 | base station | multicell, up to 254 stations | up to 8 per station, 2,000 per system | PoE, adapter not in the box |
84H79AA#ABB | Rove R8 | repeater | extends base station coverage | no capacity of its own | adapter in the box |
The base station is ordered together with handsets. We offer two, the Rove 30 (84H76AA#ABB) and the Rove 40 (84H77AA#ABB) with Bluetooth. Handsets are not in the base station box and the base station is not in a handset box.
Key features
Single cell or dual cell operation, according to the area to be covered
Up to 10 simultaneous calls in single cell mode
Coverage of up to 5,000 square feet in one cell and up to 15,000 in two, roughly 465 and 1,390 m²
Range of up to 50 metres indoors, with repeaters up to 300 metres outdoors
Up to six Poly Rove R8 repeaters per base station
DECT band 1880 to 1900 MHz for Europe, Australia, the United Kingdom and Asia Pacific
Up to 20 service subscription profiles per handset, assignments SP 1 to SP 20
A 5 V 2 A power adapter with an EU plug is included in the box
Description
The core of the system, not an accessory
The Rove B2 is the heart of a DECT system. Handsets register to it, it holds the calls and it is what connects to the PBX or cloud service. System capacity is therefore not set by the number of handsets but by the choice of base station. The B2 is intended for single or dual cell deployment, typically one floor, one building or a smaller site. For a campus or a multistorey building the B4 with multicell operation is the right answer.
How many calls will run at once
For the B2 HP quotes up to 10 simultaneous calls in single cell mode. That is the figure that decides a deal more often than the handset count. In a warehouse with twenty handsets where five people are on a call at the same time, a B2 is enough. On a site where calling is continuous and the peak exceeds ten calls, a B4 is needed. Ask about the number of simultaneous calls at peak, not only about the number of users.
Coverage is extended by repeaters, not by another base station
Range is up to 50 metres indoors. Where the signal does not reach, a Rove R8 repeater is added, and HP allows up to six of them on a B2. A repeater needs no data socket, a mains socket is enough, and it supports encrypted daisy chaining. With repeaters HP quotes up to 300 metres outdoors. Design the coverage in advance, adding repeaters later in response to user complaints works out more expensive.
Strengths and limits
Strengths
A 5 V 2 A power adapter with an EU plug is in the box, unlike on the B4
Up to six R8 repeaters per station, twice as many as on the B4
Dual cell operation covers roughly 1,390 m² without moving to a multicell system
A desk stand is part of the box
Limits and what to tell the customer
Handsets are not in the box. The Rove 30 and Rove 40 are ordered separately.
Capacity is 10 simultaneous calls in single cell mode, a larger site needs the B4.
We do not state a network port or PoE power for this code.
We do not state the number of registered handsets, only simultaneous calls and up to 20 service profiles per handset.
⚑ atlantis note
Design the system top down, from the base station to the handsets
A Rove enquiry usually arrives as a handset count. A usable specification starts elsewhere, with the number of simultaneous calls at peak and the area to be covered. That determines the choice between the B2 and the B4 and the number of R8 repeaters. Only then are the Rove 30 or Rove 40 handsets added. The reverse order ends in a follow-up order and an unhappy customer.
Do not mix goods from different regions
European Rove base stations work in the 1880 to 1900 MHz band, while the US versions of the handsets and the repeater use 1920 to 1930 MHz. The handset auto configures to the band of the base station, but even so order the whole system in European codes with the #ABB suffix and do not top it up with goods from other regions.
The B2 has the adapter in the box, the B4 does not
A detail that is missing from project budgets more often than any other. The Rove B2 has the power adapter in the box, the B4 does not, it is PoE powered and the adapter is optional, code 85W97AA#ABB. So if the design calls for several B4 stations in places without PoE, add the adapters.
Who it suits
Recommended use | a DECT base station for single cell and dual cell deployment of the Poly Rove system |
|---|---|
Position in the portfolio | wireless DECT phones, the Poly Rove system, infrastructure part |
How it differs from the other products in the range | against the B4 it is meant for one or two cells rather than a multicell system, it has the adapter in the box and it carries twice as many repeaters |
Suitable
One floor, one building or a smaller site where at peak no more than ten calls run at once. A warehouse, a workshop, a smaller hotel, a surgery, a shop.
Verify
How many calls will run at once at peak. What area and how many floors need covering. How many R8 repeaters will be required. Which PBX or cloud service the system will register to. How the station is connected to the network.
Consider another product
The Rove B4 for a multicell system, more simultaneous calls and PoE power. The Rove R8 repeater if the base station is already deployed and only the coverage is missing.
The "Verify" and "Consider another product" cards come from the experience of the atlantis team.
What the base station serves
Handsets
Rove 30 and Rove 40
Handsets register to the base station and take their band from it. Up to 10 simultaneous calls in single cell mode and up to 20 service profiles per handset.
Rove 30
Rove 40
up to 10 calls
Coverage extension
Up to six R8 repeaters
A Rove R8 repeater extends the range where the base station signal does not reach. It needs only a mains socket and supports encrypted daisy chaining.
up to 6× R8
up to 300 m outdoors
Deployment scale
Single or dual cell
In one cell it covers roughly 465 m², in two roughly 1,390 m². For a multicell system the B4 is the model to use.
1 cell
2 cells
Platform for this order code: DECT, a Poly Rove base station for single cell and dual cell deployment. SIP registration is handled by the station, not by the handset.
Connectivity, network and security
Wireless technology | DECT, the 1880 to 1900 MHz band for Europe, Australia, the United Kingdom and Asia Pacific |
|---|---|
Deployment | single cell or dual cell |
Range | up to 50 m indoors, with repeaters up to 300 m outdoors depending on the environment |
Power | external universal 5 V 2 A adapter, in the box with an EU plug |
Security | DECT encryption, DECT security certified |
Repeaters | up to six Poly Rove R8 repeaters per station |
Operating temperature | −10 to 55 °C |
Capacity, coverage and power
Simultaneous calls | up to 10 in single cell mode |
|---|---|
Number of base stations | one or two, single cell or dual cell deployment |
Service profiles | up to 20 per handset, assignments SP 1 to SP 20 |
Coverage | up to 5,000 square feet in one cell and up to 15,000 in two, roughly 465 and 1,390 m² |
Repeaters | up to six Rove R8 per station |
Power | 5 V 2 A adapter, in the box |
Compatible handsets | Poly Rove 30 and Poly Rove 40 |
Operating temperature | −10 to 55 °C |
In the box
In the box
Rove B2 base station
Power adapter with an EU plug
Desk stand
Quick start guide and safety information sheet
Not included
Handsets, Rove 30 code 84H76AA#ABB or Rove 40 code 84H77AA#ABB
Repeater Rove R8, code 84H79AA#ABB
Network cable
Any PBX licence or service
Poly+ Partner service programme
Order with it
Poly Rove 40 handset with Bluetooth84H77AA#ABB
A rugged IP65 handset with Bluetooth 4.2 for a wireless headset. Battery, cradle and adapter are all in the box.
Poly Rove 30 handset84H76AA#ABB
The same durability and endurance as the Rove 40, without Bluetooth. A headset connects via the 3.5 mm jack.
Poly Rove R8 repeater84H79AA#ABB
Up to six per this station. It needs only a mains socket, not a data one.
Li-ion battery for Rove 30 and 4085W99AA
A second battery to swap in multishift operation.
Poly Rove power adapter85W97AA#ABB
A universal adapter for the Rove 30, 40, B2, B4 and R8. A spare for this station, and required on the B4 where there is no PoE.
Poly+ Partnerby model and term
Extended support with expedited replacement, ordered together with the device.
Variants and products in the range
Range | Type | What characterises it | Intended for |
|---|---|---|---|
Poly Rove ◂ this product | DECT system | a base station, repeaters and rugged IP65 handsets | moving around a building, warehouse, production |
Poly Edge E | IP desk phone | eight models from 2 to 14 keys, classic key based operation | ordinary and demanding office positions |
Poly CCX | IP desk phone with touch | Android 12, touch display, Open SIP and Microsoft Teams versions | positions with touch operation |
Poly Trio 8300 | conference phone | SIP, Wi-Fi, Bluetooth, 3.7 m pickup | medium meeting room |
Poly Trio C60 | conference phone | SIP, Wi-Fi, Bluetooth, DECT, Teams version | larger meeting room |
What to verify before ordering and deploying
Simultaneous calls at peak: up to ten and the B2 is enough, above ten the B4 is needed
Area and number of floors: one cell covers roughly 465 m², two cells roughly 1,390 m²
Repeaters: up to six R8 units on this station, each needs a mains socket
Network connection and power: Verify a network port and PoE for this code with us before ordering
PBX or service: what the system will register to and how many SIP accounts will be needed
Handsets: the Rove 30 or Rove 40, they are not in the base station box
The atlantis team helps with every point. From the coverage design and the choice of base station through connecting to the PBX to handset registration and user training.
Management and services
System management: configuration, handset registration and service profile assignment are done on the base station, not on the handset
Poly+ Partner: local support from an experienced certified team in Czech, by phone, chat, web and video call, priority device replacement where the manufacturer ships the replacement the next business day and covers the shipping, all under the terms of the programme and for its entire validity, so the care can continue after the warranty ends
atlantis deployment: coverage design, the choice of base station and the number of repeaters, connection to a PBX or cloud service, handset registration and user training
Warranty
Standard one-year HP Poly limited warranty. Extended support with expedited replacement is provided by the Poly+ Partner programme.
FAQ
How many handsets can I connect to this station?
We do not state the number of registered handsets for this code. The station handles up to 10 simultaneous calls in single cell mode and up to 20 service profiles per handset. We therefore recommend sizing the system by the number of simultaneous calls.
How does it differ from the Rove B4?
The Rove B2 is meant for one or two cells, the Rove B4 for a multicell system of up to 254 stations and 1,000 handsets. The B2 handles up to 10 simultaneous calls, the B4 up to 8 per station and 2,000 across the system. The B2 has the adapter in the box, the B4 is PoE powered and has no adapter in the box. The B2 takes up to six repeaters, the B4 three.
Is a power adapter in the box?
Yes. On the Rove B2 a 5 V 2 A adapter with an EU plug is part of the box, together with a desk stand. On the Rove B4 there is no adapter in the box, that station is PoE powered.
What area does the station cover?
Up to 5,000 square feet in single cell mode and up to 15,000 in dual cell mode, roughly 465 and 1,390 m². Range indoors is up to 50 metres, and with R8 repeaters up to 300 metres outdoors depending on the environment.
How many R8 repeaters can be connected?
Up to six Poly Rove R8 repeaters on one Rove B2 station. On the Rove B4 it is three. A repeater needs no data socket, a mains one is enough, and it supports encrypted daisy chaining.
Which DECT band does the station work in?
The 1880 to 1900 MHz band for Europe, Australia, the United Kingdom and the Asia Pacific region. The US versions of the handsets and the repeater use 1920 to 1930 MHz. Order the whole system in European codes with the #ABB suffix.
- Manufacturer
- Poly HP
- Weight
- 0.2 kg
No attachments available.
Not sure what to choose?
We're happy to help you choose!
Every business day from 8:00 to 17:00